Flat-Liner™,
Maximum Comfort
 |
|
 |
| FlatLiner Muff, HB-640 |
Optional storage bag, SGB-30 |
Maximum Comfort
- Elvex Flat-Liner was originally designed to provide flat attenuation
for 500 Hz and up, but the market has shown no interest in this concept.
That's why we have redesigned this product to offer a medium level of
attenuation and absolutely maximum level of comfort. This is how we
maximized comfort:
This earmuff is
designed to address the issue of having the right protection, and maximum
comfort.
Low headband force
Wide ear cushions
in order to distribute the force over a larger surface area
Soft ear cushions
with an expanded vinyl for a subtle feel against the skin
A soft , padded
headband
Steel headband
tolerates temperature extremes without losing force
26 dB NRR from
certified U.S. laboratory to ANSI S3.19-1974.
32 SNR from
certified European laboratory to CE EN-352-1
This earmuff may
just have the right attenuation for most noise environments.
Read
an article about the problem with "Overprotection".
| Product Name |
Product Number |
Product Description |
Suggested
List Price |
| Flat-Liner |
HB-640 |
Flat-Liner, 8.2 oz./232 g., Steel headband, 26 NRR, 32 SNR, (CE), burgundy |
$19.40 |
| Universal Ear Muff Hygiene Kit |
HK-640 |
Hygiene Kit for HB-640 |
$7.55 |
| Safety Glass Accessories |
SBG-30 |
Storage Microfiber Bag, with drawstring, for goggles or muffs |
$6.30 |
ANSI S3-19-1974, Dr. Michael & Associates, State College,
Pennsylvania, USA
| Frequency, Hz |
125 |
250 |
500 |
1000 |
2000 |
3150 |
4000 |
6000 |
8000 |
H |
M |
L |
NRR |
| Mean Attenuation, dB |
17.8 |
25.0 |
34.0 |
35.8 |
31.9 |
35.9 |
35.2 |
38.3 |
39.2 |
32 |
29 |
23 |
26 |
| Std. Deviation |
2.4 |
2.9 |
2.6 |
2.9 |
1.6 |
3.0 |
2.4 |
3.5 |
4.1 |
CE EN-352-1:2002, INSPEC International, Greater Manchester, United
Kingdom.
| Frequency, Hz |
63 |
125 |
250 |
500 |
1000 |
2000 |
4000 |
8000 |
H |
M |
L |
SNR |
| Mean attenuation, dB |
18.1 |
15.7 |
24.4 |
34.8 |
41.1 |
33.0 |
38.4 |
37.4 |
33 |
30 |
21 |
32 |
| Std. Deviation |
3.1 |
2.8 |
2.3 |
3.3 |
2.8 |
2.2 |
3.0 |
3.4 |
| Protection |
15.0 |
12.9 |
22.1 |
31.5 |
38.3 |
30.8 |
35.4 |
34.0 |
AS/NZS 1270:2002, Testing performed by Dr. Michael &
Associates, State College, Pennsylvania
| Frequency, Hz |
125 |
250 |
500 |
1000 |
2000 |
4000 |
8000 |
SLC(80) |
| Mean Attenuation, dB |
18.8 |
24.8 |
35.2 |
38.8 |
30.2 |
38.4 |
40.5 |
-
30.1
- Class 5
|
| Std. Deviation |
3.8 |
3.5 |
3.7 |
3.2 |
3.4 |
2.8 |
3.0 |
| Mean - Std. Deviation |
15.0 |
21.3 |
31.5 |
35.6 |
26.8 |
35.6 |
37.5 |
|
|